Conductor: Concentric Stranded annealed copper wire Insulation: PVC Black color Core: 2-30 Core Identification: Printed White number on the surface of Black insulation Filler: Suitable filler Binding tape: Suitable tape Inner sheath: PVC Black color Armour: Galvanized steel wire Binding tape: Suitable tape Outer Sheath: PVC Black color Application: For use in duct, tray and for direct burying in ground. The cable subjects to immerse in water all the line.
sales@shandonghuadongcable.com
Specifications
Application: Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction.
1: AC rated voltageU0/U:300/500V. Long term working temperature of cable conductor is 70oC & 105oC for cable with PVC insulation, 70oC for cable with PE insulation and 90oC for cable with XLPE insulation.(XLPE insulation includes saline XLPE & irradiation XLPE insulation.)
2: Min. environment temperature is -40oC for fixed ?laying and -15oC for non-fixed laying. Environment temperature shall be no less than 0oC for installing.
3: Min.bending radius allowed by cable is no less than 6 times that of cable OD for non-armored soft cable or braided shielding cable and 12 times that of cable OD for cable with metallic tape wrapped shielding or steel wire/steel tape armor.
Standards:
BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification
Technical information:
Conductor: Bare stranded copper conductor–class 5 IEC228; ? ?Insulation/Sheath: PVC or PVC of flame retardance and other property,Operating temperature: 70°C
Remark:
1.the cable can be with copper braided screen or steel wire armor and other features.
2.The cable can be of flame retardance, fire resistance and environment friendly or other property.
4 Core CVV-S 0.6/1KV Control Cable Technical Parameter
No.of core
Nominal cross-sectional area
No.&dia.of wires
Thickness of insulation
Thickness of inner sheath
Diameter of steel wire armour
Thickness of outer sheath
Overall diameter (Approx.)
Maximum conductor (at20C)
Minimum insulation resistance (at70C)
Cable weight (Approx.)
Standard Length
mm2
No./mm
mm
mm
mm
mm
mm
Ohm/km
Ohm/km
kg/km
m
4
0.5
7/0.30
0.8
1.2
0.8
1.8
16.5
36
0.0162
380
500/D
0.75
7/0.37
0.8
1.2
0.8
1.8
17
24.5
0.0142
410
500/D
1
7/0.40
0.8
1.2
0.8
1.8
17
18.1
0.0135
425
500/D
1.5
7/0.50
0.8
1.2
0.8
1.8
18
12.1
0.0115
480
500/D
2.5
7/0.67
0.8
1.2
1.25
1.8
20.5
7.41
0.0093
715
500/D
4
7/0.85
1
1.2
1.25
1.8
23
4.61
0.0092
915
500/D
6
7/1.04
1
1.2
1.25
1.8
24.5
3.08
0.0078
1075
500/D
5 Core CVV-S 0.6/1KV Control Cable Technical Parameter
No. of core
Nominal cross-sectional area
No.& dia.
Thickness
Thickness of inner sheath
Thickness
Overall diameter (Approx.)
Maximum conductor resistance
Minimum insulation resistance
Cable
Standard Length
of wires
of insulation
of outer sheath
(at20C)
(at70C)
weight (Approx.)
5
mm2
No./mm
mm
mm
mm
mm
Ohm/km
Ohm/km
kg/km
m
0.5
7/0.30
0.8
1
1.8
14.5
36
0.0162
250
500/D
0.75
7/0.37
0.8
1
1.8
15
24.5
0.0142
280
500/D
1
7/0.40
0.8
1
1.8
15.5
18.1
0.0135
295
500/D
1.5
7/0.50
0.8
1
1.8
16.5
12.1
0.0115
345
500/D
2.5
7/0.67
0.8
1
1.8
18
7.41
0.0093
445
500/D
4
7/0.85
1
1
1.8
20.5
4.61
0.0092
620
500/D
6
7/1.04
1
1
1.8
22.5
3.08
0.0078
780
500/D
6 Core CVV-S 0.6/1KV Control Cable Technical Parameter
No. of core
Nominal cross-sectional area
No.& dia.
Thickness
Thickness of inner sheath
Thickness
Overall diameter (Approx.)
Maximum conductor resistance
Minimum insulation resistance
Cable
Standard Length
of wires
of insulation
of outer sheath
(at20C)
(at70C)
weight (Approx.)
6
mm2
No./mm
mm
mm
mm
mm
Ohm/km
Ohm/km
kg/km
m
0.5
7/0.30
0.8
1
1.8
15.5
36
0.0162
270
500/D
0.75
7/0.37
0.8
1
1.8
16
24.5
0.0142
305
500/D
1
7/0.40
0.8
1
1.8
16.5
18.1
0.0135
320
500/D
1.5
7/0.50
0.8
1
1.8
17.5
12.1
0.0115
375
500/D
2.5
7/0.67
0.8
1
1.8
19
7.41
0.0093
290
500/D
4
7/0.85
1
1
1.8
22
4.61
0.0092
685
500/D
6
7/1.04
1
1
1.8
24
3.08
0.0078
865
500/D
7 Core CVV-S 0.6/1KV Control Cable Technical Parameter
No. of core
Nominal cross-sectional area
No.& dia.
Thickness
Thickness of inner sheath
Thickness
Overall diameter (Approx.)
Maximum conductor resistance
Minimum insulation resistance
Cable
Standard Length
of wires
of insulation
of outer sheath
(at20C)
(at70C)
weight (Approx.)
7
mm2
No./mm
mm
mm
mm
mm
Ohm/km
Ohm/km
kg/km
m
0.5
7/0.30
0.8
1
1.8
15.5
36
0.0162
275
500/D
0.75
7/0.37
0.8
1
1.8
16
24.5
0.0142
315
500/D
1
7/0.40
0.8
1
1.8
16.5
18.1
0.0135
330
500/D
1.5
7/0.50
0.8
1
1.8
17.5
12.1
0.0115
395
500/D
2.5
7/0.67
0.8
1
1.8
19
7.41
0.0093
520
500/D
4
7/0.85
1
1
1.8
22
4.61
0.0092
730
500/D
6
7/1.04
1
1
1.8
24
3.08
0.0078
930
500/D