Voltage: 0.6/1KV
Conductor: AAC/AAAC/ACSR
Insulation: XLPE
Cores: 2+1 Core
Standard: NFC 33-209 /ICEA S-476/BS7870-5/ IEC60502 /AS/NZS or other Standard
Packaging: Iron Or Wooden Drum
Duplex Service drop cable Description:
Duplex Overhead Service Drop Cable assemblies consist of one insulated phase conductor and a bare neutral conductor. They are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles.Their use should be limited to circuits not exceeding 600 volts phase-to-phase and a 90°C normal conductor temperature.

Duplex Service drop cable Construction:
Cable assemblies are available with the following neutral conductors;
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded;
Aluminum alloy 6201-T81, concentric-lay-stranded
Insulation Material:
1.The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE).
The XLPE insulation meets the requirements of ANSI/ICEA S-76-474-2004 (Standard for Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts).
2.Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request.
3. The LLDPE insulation meets the requirements of ASTM Standard D1248-05 (Standard Specification for Polyethylene Plastics Molding and Extrusion Materials).

Specification:
ANSI/ICEA S-76-474 Neutral-supported power cable assemblies with weather-resistant extruded insulation rated 600V
ASTM B-230 Aluminum wire, 1350-H19 for Electrical Purposes
ASTM B-231 Aluminum conductors, concentric lay-stranded
ASTM B-232 Aluminum conductor, concentric-lay-stranded,coated steel-reinforced(ACSR)
ASTM B-399 Concentric-lay-stranded 6201-T81 aluminum alloy conductor
ASTM B-498 Zinc-Coated steel core wire for ACSR
We can also supply other international Standard, eg:BS/ICEA/NFC/VDE/DIN standard etc

| Code Name | Phase conductor | Bare Neutral Message | Nominal Weight | Allowable Ampacity ( A ) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| ( kg/km ) | ||||||||||
| Size & No.of wires | Insulation Thick(mm) | Nominal Dia.(mm) | Size & No.of wires | Rated Strength(kg) | XLPE | Al | Total | |||
| Bare | OD | |||||||||
| AAC | ||||||||||
| Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 43258 | 255 | 20.8 | 72.9 | 94 | 78 |
| Collie | 43258 | 1.14 | 4.6 | 6.9 | 43258 | 255 | 23.8 | 72.9 | 97 | 78 |
| Cocker | 43258 | 1.52 | 4.6 | 7.7 | 43258 | 255 | 32.7 | 72.9 | 106 | 78 |
| Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 43258 | 400 | 26.8 | 114.6 | 141 | 103 |
| AAAC | ||||||||||
| Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 43258 | 499 | 20.8 | 72.9 | 94 | 78 |
| VIzsla | 43258 | 1.14 | 4.6 | 6.9 | 43258 | 499 | 23.8 | 72.9 | 97 | 78 |
| Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 43197 | 798 | 26.8 | 116.1 | 143 | 103 |
| ACSR | ||||||||||
| Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 2006-06-01 | 540 | 20.8 | 72.9 | 94 | 78 |
| Shepherd | 43258 | 1.14 | 4.6 | 6.9 | 2006-06-01 | 540 | 23.8 | 72.9 | 97 | 78 |
| Retriever | 43258 | 1.52 | 4.6 | 7.7 | 2006-06-01 | 540 | 32.7 | 72.9 | 106 | 78 |